Order: sample-order.pdf · Plans: sample-plans.pdf
Coverage
Reviewed: Kitchen perimeter and island (plan pages: 2, 3, 4, 5)
Documents received: Order (ACK), 40 lines, Plans and elevations, 7 pages
Missing: Appliance specs; Renders
Not checked:
- Not checked: laundry room (plan page 6), no order supplied for it
- Not checked: wet bar (plan page 7), no order supplied for it
- Spec book: sample pack only, page references are fictional
Critical (4)
Elevation page 3 shows the pantry with an upper door and a lower door, break at 59". ACK item 4 BR368424 has a single door per side and no door style or horizontal partition. Doors over 48" high are built with a center rail, so the plan and the build differ either way.
Check: Door layout vs plan on tall units · Book: Sample pack: doors over 48" get an intermediate rail (fictional page reference)
Elevation page 2 shows the middle wall stack 36" wide x 51" high. ACK item 7 WST3654-15 is 36 x 54 with a width modifier only. No reduced-height line follows it. Height was not checked after the modifier.
Check: Gap detection (Level 1)
Elevation page 4 labels the island cabinet B18R. ACK item 3 B18 with a trash-can kit shows hinge side blank. B18 is a door base, not a drawer unit, so the blank hinge side is wrong even with the kit on the line.
Check: Handing suffix vs hinge side
Elevation page 4 labels DB18 left and right of the fridge opening. ACK item 11 DB18 has quantity 1. The second DB18 and its fridge-side finished end are missing.
Check: Count symmetry
Verify (4)
Both panels are REP on the same run. Item 15 reads banded on both long edges. Item 16 reads No Edges. The book makes banding optional, so this is a question: is the panel exposed, and do you want the band?
Check: Peer check · Book: Sample book: edges may be banded on request (fictional page reference)
ACK item 8 WST2454-18 carries the description 30" TOP SECTION. The plan shows a 30" top section. No change-section-height modifier. The code decides what is built, so as written this builds an 18" top section.
Check: Code vs description
ACK item 9 BR368424 is an 84" cabinet with the line RH reduced height to 87". The plan shows 87". Reduced height can only reduce. This should be an increased height. The factory has to interpret it.
Check: Modification wording
ACK item 20 is 24 wide x 12.5 deep. The plan shows a face 12.5 wide. If the unit is rotated, the order is right.
Check: Rotation check
Unknown (1)
Plan page 4 says 2" thick shelves, parts to be sent, built on site. No ACK line supplies the sheet material. Reveal does not guess a quantity. Ask for the take-off and cut list.
Check: Callout to order line
Info (2)
Tall panels sold as full height stock are cut on site, so this is not a mismatch.
Check: Oversize tall panels
Plan perimeter including jogs is 38 ft. Ordered crown totals 44 ft.
Check: Linear molding
Line by line
What the review matched, so you can see its work.
| Item | Code | Base | Mods | As built | Plan | Result |
|---|---|---|---|---|---|---|
| 3 | B18 *TC18* | 18 x 34.5 x 24 | none | 18 x 34.5 x 24 | p.4 B18R, 18 wide | Mismatch |
| 4 | BR368424 | 36 x 84 x 24 | none | 36 x 84 x 24 | p.3 36 x 84, door break at 59 | Mismatch |
| 7 | WST3654-15 | 36 x 54 x 13 | none | 36 x 54 x 13 | p.2 36 x 51 | Mismatch |
| 8 | WST2454-18 | 24 x 54 x 13 | none | 24 x 54, top section 18 | p.2 24 x 54, top section 30 | Mismatch |
| 9 | BR368424 | 36 x 84 x 24 | RH to 87 | 36 x 87 x 24 | p.3 36 x 87 | Cannot verify |
| 11 | DB18 | 18 x 34.5 x 24 | none | 18 x 34.5 x 24, qty 1 | p.4 DB18 x 2 | Mismatch |
| 12 | DB30 | 30 x 34.5 x 24 | none | 30 x 34.5 x 24 | p.4 30 x 34.5 x 24 | Match |
| 13 | W3015 | 30 x 15 x 13 | none | 30 x 15 x 13 | p.5 30 x 15 x 13 | Match |
Checked and matched
- Finished ends on items 12 and 13
- Run length, north wall
- Hinge sides on wall cabinets
Could not run
- Appliance cut-out check (no appliance specs)
- Door look vs render (no renders supplied)
Your review checklist
For your own use. Reveal does not collect this page.
- Every finding checked against the plans and the order
- Finished sides and ends confirmed
- Toe kick height confirmed
- Appliance openings and panel backers confirmed
- Molding quantities checked against the plan perimeter
- Signed off by the designer